Notations#
Indices and Sets#
Indices |
Set |
---|---|
\(c \in C\) |
where \(C\) is the set of countries |
\(d \in D\) |
where \(D\) is the set of types of days or weeks |
\(f \in F\) |
where \(F\) is the set of fuels |
\(g \in G\) |
where \(G\) is the set of generators that can be built or the set of technology-specific types of aggregated generators |
\(q \in Q\) |
where \(Q\) is the set of seasons or quarters |
\(h \in H\) |
where \(H\) is the set of electrolyzers that can be built |
\(y \in Y\) |
where \(Y\) is the set of years considered in the planning model |
\(z, z_2 \in Z\) |
where \(Z\) is the set of zones/regions modeled |
\(sc \in S\) |
where \(S\) is the set of flags and penalties used to include/exclude certain features of the model |
Subsets considered |
|
\(EN, NG \in G\) |
where \(EG\) and \(NG\) is a partition of set \(G\) and the former (EG) contains generators existing at the starting year of the planning horizon and the latter contains candidate generators[1] |
\(DC, NDC \in G\) |
where \(DC\) and \(NDC\) are partitions of set \(G\) separating generators with a CAPEX cost constant over the modeling horizon and those generators that have costs varying over time. This feature is mainly developed to account for technologies that show cost reductions due to technological improvements and manufacturing advances. |
\(EH, NH \in H\) |
where \(EH\) and \(NH\) is a partition of \(H\) set and the former (\(HG\)) contains electrolyzers existing at the starting year of the planning horizon and the latter contains candidate electrolyzers[2] |
\(DH, NDH \in H\) |
where \(DH\) and \(NDH\) are partitions of set H separating electrolyzers with a CAPEX cost constant over the modeling horizon and those electrolyzers that have costs varying over time. This feature is mainly developed to account for technologies that show cost reductions due to technological improvements and manufacturing advances. |
\(so \in G\) |
PV unit linked to a storage unit as a partition of set \(G\) (this is the PV part of PV linked with storage) |
\(stp \in st\) |
Storage unit linked to a PV plant as a partition of set \(G\) (this is the storage part of PV linked with storage) |
\(MD \in D\) |
where \(MD\) is a subset of days the planner expects the minimum load levels to be binding |
\(RE \in F\) |
where \(F\) is a subset of set considered as renewable according to regulatorβs criteria[3] |
\(RG \in G\) |
Subset of renewable generators |
\(map_{c,z}\) |
includes the subset of zones that correspond to each country |
\(map_{g,f}\) |
includes valid combinations of fuels and generators; subset of the set \(G x F\) |
\(map_{eg,ef}\) |
includes combinations of existing and candidate generators; subset of set \(EG x NG\) |
\(map_{g,z}\) |
includes the subset of generators that correspond to each zone |
\(map_{h,z}\) |
includes the subset of electrolyzers that correspond to each zone |
Variables#
Non-negative decision variables |
|
---|---|
\(π΄ππππ‘ππππππππππ πππ_{π§,π§2,π¦}\) |
Additional number of lines between z and z2 in year y |
\(ππ’πππ_{g,y}\) |
Generator investment in MW |
\(ππ’ππππ»2_{h,y}\) |
Electrolyzer investment in MW |
\(ππ’πππ‘πΆπππππ_{g,y}\) |
Integer variable to model discrete unit capacity |
\(ππ’πππ‘πΆππππππ»2_{h,y}\) |
Integer variable to model discrete unit capacity |
\(ππ’πππ‘πππππ πππ π πππ_{z,z2,y}\) |
Integer variable to model number of new transmission lines added between z and z2 in year y |
\(πππ_{g,y}\) |
Generator capacity available at year in MW |
\(ππππ»2_{h,y}\) |
Electrolyzer capacity available at year in MW |
\(πΆπ2πππππ π‘ππ_{c,y}\) |
Annual country CO2 emissions above the system emissions constraint cap |
\(ππππ π ππππ _{z,y}\) |
Total system emissions of carbon dioxide in tons |
\(ππππ π ππππ _ππ_{z,y}\) |
Emissions of carbon dioxide in tons per zone |
\(ππ₯ππππ‘πππππ_{z,q,d,t,y}\) |
External price driven export in MW |
\(ππ’πππ»2ππ’πππ‘ππ_{z,q,y}\) |
Hydrogen fuel consumption for electricity production hydrogen produced intended for re-circulation in the power sector in (MMBTU per quarter and year) |
\(ππ’πππ»2_{z,q,y}\) |
Hydrogen fuel consumption for electricity production hydrogen produced intended for re-circulation in the power sector in (MMBTU per year) |
\(ππ’ππ_{z,f,y}\) |
Fuel consumption in MMBTU |
\(πππ_{g,f,q,d,t,y}\) |
Generator output in MW |
\(ππππΆππ_{g,z,q,d,t,y}\) |
Power output of the solar panel in MW |
\(ππππππ‘πππππ_{z,q,d,t,y}\) |
External price driven import in MW |
\(π»2ππ€ππΌπ_{h,q,d,t,y}\) |
Power drawn by electrolyzer h in MW |
\(πππ‘πππ_{g,y}\) |
Capacity in MW retired |
\(πππ‘ππππΆπππππ_{g,y}\) |
Supplementary integer variable to model discrete unit capacity |
\(πππ‘ππππΆππππππ»2_{h,y}\) |
Supplementary integer variable to model discrete unit capacity |
\(πππ πππ£π_{g,q,d,t,y}\) |
Spinning reserve requirement met in MW |
\(π π‘πππππ_{st,q,d,t,y}\) |
Level of energy in MWh stored in storage unit |
\(π π‘πππππ_πππ_{st,q,d,t,y}\) |
Power injected in MW in storage unit is charged during hour |
\(π π‘πππππ_πππππππ‘π¦_{st,q,d,t,y}\) |
Total deployed energy storage capacity in MWh for storage unit |
\(π π‘ππππππΆππ_{g,z,q,d,t,y}\) |
Level of energy in MWh stored in CSP unit at zone |
\(π π‘ππππππΆπππππ_{g,z,q,d,t,y}\) |
Power level in MW at which the CSP storage unit is charged during hour |
\(π π‘ππππππΆππππ’π‘_{g,z,q,d,t,y}\) |
Power level in MW at which the CSP storage unit is discharged during hour |
\(π π’ππππ’π _{z,q,d,t,y}\) |
Surplus generation in MW |
\(π’ππππ‘π·ππ_{z,q,d,t,y}\) |
Annual system CO2 emissions above the system emissions constraint cap |
\(π’ππππ‘π»2πΈπ₯π‘πππππ_{z,q,y}\) |
Active power in MW flowing from to |
\(π’ππππ‘π ππ _{z,y}\) |
Unmet demand in MW (or equivalently violation of the load balance constraint) |
\(π’ππππ‘ππ ππ ππ_{z,q,d,t,y}\) |
Unmet quantity of hydrogen in MW (or equivalently violation of the external demand for hydrogen balance constraint) |
\(π’ππππ‘ππ ππ ππ_{q,d,t,y}\) |
Violation of the planning reserve constraint in MW |
\(unmetSResZo\) |
Violation of the zonal/regional spinning reserve constraint in MW |
\(unmetSResSY\) |
Violation of the system-level spinning reserve constraint in MW |
Variables for modeling objective function |
|
---|---|
\(npvcost = \sum_{z,y} ReturnRate_y \cdot WeightYear_y \cdot totalcost_{z,y}\) |
Net present value of power system cost over the whole planning horizon; objective function that optimization model tries to minimize |
\(totalcost_{z,y} = fixedcost_{z,y} + variablecost_{z,y} + reservecost_{z,y} + usecost_{z,y} + usrcost_{z,y} + carboncost_{z,y} + CO2backCost_y + TradeCost_{z,y} + CostTransmissionAdditions_{z1,z2,y} + CurtailmentCost_{z,y} + SurplusCost_{z,y} + usrcostH2_{z,y}\) |
Annual system cost in constant prices |
Model formulation#
Objective function and its components#
The objective function minimizes the net present value of total system costs:
The total cost for each zone z and year y consists of:
Fixed costs include capital recovery and fixed O&M for both generation and hydrogen units:
Annualized capital expenditure for generation and hydrogen units:
Variable costs include generation fuel costs and hydrogen production costs:
Reserve costs for maintaining system reliability:
Costs associated with unmet demand:
Costs for unmet reserve requirements:
Carbon-related costs including emissions tax and backstop measures:
Additional cost components:
Transmission network constraints#
Power balance constraint for each zone:
Transmission capacity constraints:
Import/export constraints:
System requirements#
System-wide reserve requirements:
Reserve offer limits:
Planning reserve margin requirements:
Generation constraints#
Generation capacity and reserve constraints:
Ramping constraints:
Minimum capacity factor requirements:
Availability constraints:
Renewable generation#
Concentrated Solar Power (CSP) Generation#
The following equations govern the operation of CSP plants, including their thermal storage capabilities and generation limits.
Storage level cannot exceed storage capacity.
CSP generation is determined by solar resource profile and plant characteristics.
Total CSP generation cannot exceed capacity.
Energy balance equation for CSP operation.
Storage level evolution over time.
Time Consistency of Power System Additions and Retirements#
These equations ensure proper tracking of capacity additions and retirements over time.
Capacity evolution for existing generators.
Initial capacity for existing generators.
Capacity during operational period.
Zero capacity after retirement.
Capacity evolution for new generators.
Initial capacity for new generators.
Maximum capacity constraint.
Zero capacity before commissioning.
Storage Constraints#
The following equations govern the operation of storage systems.
Initial storage level.
Storage level evolution.
Storage injection for PV storage.
Maximum injection rate.
Maximum storage level.
Ramping down constraint.
Ramping up constraint.
Storage capacity evolution for existing storage.
Storage capacity evolution for new storage.
Initial storage capacity for new storage.
Minimum storage capacity requirement.
Maximum storage capacity limit.
Total storage capacity build limit.
Investment Constraints#
These equations govern investment decisions for new capacity.
Maximum total new capacity.
Minimum total new capacity.
Maximum build limit for existing generators.
Annual build limit.
Discrete capacity additions.
Discrete capacity retirements.
No builds before commission year.
Fuel availability constraint.
Fuel consumption calculation.
Capital investment constraint.
Environmental Policy#
These equations enforce environmental constraints.
Zone emissions calculation.
Zone emissions cap.
System emissions calculation.
System emissions cap.
CCS Retrofits#
CCS retrofit constraint.
Green Hydrogen Production#
These equations govern green hydrogen production facilities.
Existing hydrogen capacity evolution.
New hydrogen capacity evolution.
Initial hydrogen capacity.
Maximum existing hydrogen capacity.
Maximum new hydrogen capacity.
Discrete hydrogen capacity additions.
Discrete hydrogen capacity retirements.
Hydrogen production availability constraint.
Hydrogen balance equation.
Quarterly hydrogen fuel balance.
Maximum hydrogen production rate.
Hydrogen production ramping down constraint.
Hydrogen production ramping up constraint.
Renewable energy allocation between grid and hydrogen.
Power input to hydrogen production.
Renewable power to hydrogen balance.
Renewable power to grid balance.